Posted By Anas Dawas 10-05-2022 04:35 PM
Found In Egroup: Integrated Buildings & Structures
\ view thread
I am always trying to start with my knowledge and after that , any body can correct me ,  1) I think always that outrigger can not cause soft story or weak story because it lead to uniformly distributed stiffness and strength for few floors ,  and we are adding outrigger to reduce lateral deflection ...
Posted By Anas Dawas 10-04-2022 11:06 AM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Hi Engineers & Professionals  I would like to ask about the effect of outrigger systems in 300 m high rise building shown in the picture  !!  I) What is the type of irregularity that can outrigger imposed in structure ? ( weak story , soft story , both of them , others  ) 2) When we check weak story ...
Posted By Anas Dawas 10-04-2022 10:49 AM
Found In Egroup: Integrated Buildings & Structures
\ view thread
I am happy to share my experience with you  I appreciate your help , Regards , ------------------------------ Anas Dawas Aff.M.ASCE Engineer RAK ------------------------------ ------------------------------------------- Original Message: Sent: 10-03-2022 07:26 AM From: Andre Newinski ...
Posted By Anas Dawas 10-01-2022 11:54 AM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Eng. Andre Newinski ,  This picture is related to the previous comment Regards , ------------------------------ Anas Dawas Aff.M.ASCE Engineer RAK ------------------------------ ------------------------------------------- Original Message: Sent: 09-30-2022 02:44 PM From: Anas Dawas ...
Posted By Anas Dawas 10-01-2022 01:42 AM
Found In Library: Integrated Buildings & Structures
Posted By Anas Dawas 09-30-2022 02:51 PM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Thank you Eng. Andre Newinski , This is perfect discussion with you especially that you gave me enough time to do some analysis to define clearly the effect of  abrupt change ,  I will add my opinion , If we look to the attached picture (not picture in main post ) , we can find that : 1) In picture ...
Posted By Anas Dawas 09-30-2022 02:51 PM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Thank you , I believe that engineering judgment always is very important  in such cases but we are designing much projects and much mega projects and these points still not understood well for most of our engineers due to simplicity of the code provisions in comparing with complexity of real life ...
Posted By Anas Dawas 09-30-2022 12:03 PM
Found In Egroup: Integrated Buildings & Structures
\ view thread
you are perfect and great I will comment my opinion as soon as possible ------------------------------ Anas Dawas Aff.M.ASCE Engineer RAK ------------------------------ ------------------------------------------- Original Message: Sent: 09-30-2022 03:59 AM From: Andre Newinski Subject: Over-strength ...
Posted By Anas Dawas 09-28-2022 01:51 PM
Found In Egroup: Integrated Buildings & Structures
\ view thread
As per my understanding (someone can correct me) , Transfer beam (TR) and column B should only be designed for over strength factor , ------------------------------ Anas Dawas Aff.M.ASCE Engineer RAK ------------------------------ ------------------------------------------- Original Message: ...
Posted By Anas Dawas 09-28-2022 10:46 AM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Dear sir ,  I would like to ask about the case shown in the attached picture for a building with intermediate frame system as a LFRS . Which elements must be designed for over strength factor as per ASCE provisions ? ------------------------------ Anas Dawas Aff.M.ASCE Engineer RAK ...