Skip main navigation (Press Enter).
Log in
Toggle navigation
Collaborate Home
Communities
My Communities
All Communities
Communities of Practice
Get Started
New User
My Profile
My Privacy Settings
My Email Preferences
FAQs
Browse
Announcements
Blogs
Discussion Posts
Glossary
Library Entries
Connect
Directory
Events
Volunteer
Member Home (Admin)
Log in
New Login Experience Coming!
ASCE will launch a new login experience in early 2026.
List of Contributions
×
Contact Details
W.B. Clausen Structural Engineers
×
Enter Password
Enter Password
Confirm Password
Ribbons
Badges
Mr. Elliot House, P.E.
W.B. Clausen Structural Engineers
Profile
Connections
Contacts
Contributions
Achievements
List of Contributions
Contributions
1 to 5 of 6 total
search criteria =
ALL
RE: Building extension project
Posted By
Elliot House
07-04-2019 07:23 PM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Where is the hotel located? What Code are you using? What is the hotel constructed? I would make sure that the client understands that the building will(should) come up to current Code due to the vertical addition. The roof was likely not designed to floor loads and will probably need to ...
RE: Grout Bases for Columns
Posted By
Elliot House
06-16-2019 08:50 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
I'd double check your details for the job and ask around the office. If you still think the base plates are not built to detail call the contractor. If no resolution is met a progress report to the client may be needed. ------------------------------ Elliot House P.E.,S.M.ASCE W.B. Clausen Structural ...
RE: Composite Floor Deck Diaphragm Shear Connector Tests under Lateral Seismic Loads
Posted By
Elliot House
03-17-2019 09:40 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Very interesting! Thanks. Hopefully there will be links to the test data and research. Cheers, ------------------------------ Elliot House W.B. Clausen Structural Engineers Emeryville CA (415)444-4144 ------------------------------
RE: What is intial sizing of heavily loaded slabs and beams more than 25 KN/m
Posted By
Elliot House
02-26-2019 07:50 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Hi, there. Is the slab on grade? If so look up slab load on an elastic foundation to get your design criteria. You don't need much. You have specified a line load, do you mean an area load? Don't forget to specify construction joints, control joints, compaction, and review concrete mix. Don't use ...
RE: Initial Structural Frame Softness
Posted By
Elliot House
01-23-2019 02:32 PM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Hi, Colton. Are the loads expected service loads? I would check the fabricators pre-camber too, if it wasn't cambered enough it could cause higher deflections and higher stresses on the bolted connections. My two cents. ------------------------------ Elliot House P.E., S.M.ASCE W.B. Clausen ...
«
1
2
»
Copyright 2025. All rights reserved.
Powered by Higher Logic
×
Community Tags
Add a tag
x
User Tags may not contain the following characters: @ # $ & :