Posted By Jacob Trapp 06-30-2025 08:35 PM
Found In Egroup: Peer-to-Peer Standards Exchange
\ view thread
To make it simple, let's use the following assumptions: Ground snow ASCE 7-16 = 35 psf. Ground snow ASCE 7-22 = 50 psf. Check service level roof pressure for an identical 4ft high snow drift. Density = 0.13pg +14 18.55 pcf (ASCE 7-16) 20.5 pcf (ASCE 7-22) Drift pressure = load factor ...
Posted By Jacob Trapp 06-26-2025 03:10 PM
Found In Egroup: Peer-to-Peer Standards Exchange
\ view thread
ASCE 7-22 updated the ground snow load map to reflect ultimate design loads, which increased the values. At the same time, the service-level load combinations now apply a 0.7 multiplier to snow loads. My concern is with how snow drifts are calculated. Drift loads are based on the drift height and the ...