List of Contributions

Contact Details

Pendharkar & Associates Ltd

Institute Ribbons and Badges

Contact information, job title, education, and license are populated by the ASCE Membership database. You can edit your account here. Please allow 12 hours for the changes to appear in ASCE Collaborate. 

Mr. Shashank Pendharkar

Pendharkar & Associates Ltd

Contributions

1 to 5 of 12 total
Posted By Shashank Pendharkar 09-24-2019 07:48 AM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Ashwin You should clarify whether girder is located e.g. in a Building or Bridge or any other structure e.g. industrial building to support equipment load. If you have a drawing/ skech which shows ocation of girder then that will be help. For a building, assuming concrete floor, you should take dead ...
Posted By Shashank Pendharkar 09-06-2019 07:46 AM
Found In Egroup: Integrated Buildings & Structures
\ view thread
In 2017 we strengthened foundation of a 17 story residential building in Dar es Salaam, Tanzania, comprising 800 thk Raft by drilling 10m deep 75mm dia. micro-piles of 300kN capacity each into Sandy Clay soil strata. Micro-piles were chosen because basement with its limited by height could be accessed ...
Posted By Shashank Pendharkar 02-10-2019 08:56 AM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Our bridge comprises of 5 Nos. steel plate girders, each of 61.4m length and 60.8m c/c of bearings + 225mm thk concrete deck slab. Overall Bridge width is 11.15m. Each girder weighs 140 tons including all the steel work. Deck cross section comprises of 5 plate girders at 2125mm c/c with two cantilevered ...
Posted By Shashank Pendharkar 02-01-2019 07:43 AM
Found In Egroup: Integrated Buildings & Structures
\ view thread
For existing buildings where limited or no information is available we have used 'reverse' engineering approach i.e. to take inventory of existing structure, assess its condition and estimate residual load carrying capacity. Then modify/strengthen the structure as dictated by additional load requirements. ...
Posted By Shashank Pendharkar 03-29-2018 10:22 AM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Thanks for the comments. 1. We followed BS and therefore I mentioned the reference code. Other codes may have different requirements. 2. Slab deflections have been checked in compliance with BS (span/depth ratio) and accordingly reinforcement is increased in midspan. 3. Fire resistance - 2 hour ...