Mr. Christian Parker, P.E., M.ASCE
Profile
Connections
Contacts
Contributions
Achievements
List of Contributions
Contributions
1 to 5 of 38 total
search criteria =
ALL
RE: Scaling of RSA Results to Match ELF Base Shear for Towers with Podiums/Basements (ASCE 7)
Posted By
Christian Parker
10-27-2025 11:46 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Mahmoud, Is there something in ASCE 7 that drives the requirement to scale at top of podium? My interpretation is that scaling is intended to be at the base of the structure, not intermediate levels. I do feel that the mass of a podium can contribute to story shears above in real life, although the ...
RE: If you See Something, Say Something
Posted By
Christian Parker
04-04-2024 10:36 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Mitch, I found the article very insightful, but I wonder if we're asking too much of a public numb to visible damage in a field where the difference between critical issues and cosmetic damage is not obvious. I love explaining lateral-torsional buckling because it's so intuitive once you can picture ...
RE: Seismic resistance in precast slab and beam connections comparison with conventional slab and beam connection
Posted By
Christian Parker
04-01-2024 08:06 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Hello Shreyans, Can you clarify what you are asking? I'm not seeing a question in your post. ------------------------------ Christian Parker P.E., M.ASCE Structural Project Engineer Chicago IL ------------------------------
RE: The building is affected by the wind and earthquake at the same time.
Posted By
Christian Parker
02-26-2024 11:13 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
I had just entered practice when this thought first occurred to me, and I remember being alarmed and getting very curious. I eventually concluded that this is not cause for concern. If we assume no correlation between wind and seismic (more on that later), the probability of a 700-year design wind ...
RE: Factor of Safety for Net Uplift Tension in Buildings
Posted By
Christian Parker
01-24-2024 10:17 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
I think in the instance of ballasted solar arrays, using D+0.6W vs. 0.6D+0.6W makes a significant difference, since the design output is the required amount of dead load rather than member strength. You'll specify 40% less ballast if you design for 0.6D+0.6W. I certainly see your point on geotech. ...
«