Posted By Rushikesh Trivedi 03-16-2020 01:10 PM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Rocio, In such a case I think it won't affect the foundation because 1) the pipe is insulated & 2) pipe is not supported directly on mat. And also, temperature mentioned is not very high ! You can utilize simple text book formulae to calculate the temperature drop at surface of concrete using thermal ...
Posted By Rushikesh Trivedi 03-12-2020 06:17 AM
Found In Egroup: Integrated Buildings & Structures
\ view thread
​Hello, AISC Design Guide 17 Section 5.4.11 discusses this topic in detail. Table 5-2 summarizes weldability of different grades and only A307 Grade A or B with Supplementary requirements S1 offers better control compared to all other grades based on CE limit. An indication of 'Relative Weldability' ...
Posted By Rushikesh Trivedi 03-05-2020 07:41 AM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Hello, Can you provide more information ? What is the shape of foundation / arrangement and sizes ? 70 degrees C is not much. Is it a sustained temperature in the equipment or just a case of design condition (occasional) ? On the side note: Concrete pavements in middle east / any other warmer regions ...
Posted By Rushikesh Trivedi 01-30-2020 08:14 AM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Hello , On a revamp project while analyzing for increased forces, I came across a case where a doubler plate is required in column to safeguard against excessive web panel ​zone shear. However, as it is a modification work, welding is not a preferred option as it requires several precautions to be ...