Posted By Joseph Johnston 05-08-2018 09:59 AM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Ryan - For trussed towers refer to the TIA (Telecommunications Industry Association) design standard. TIA-222-G. Wind forces are calculated based on the solidity ratio of one face and applied on one face. Using an open structure area load is extremely conservative. Shape factors can be complicated with ...