Mark Myers, P.E., M.ASCE
Profile
Connections
Contacts
Contributions
Achievements
List of Contributions
Contributions
1 to 5 of 8 total
search criteria =
ALL
RE: Why SE Licensure?
Posted By
Mark Myers
01-28-2023 03:35 PM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
SE should be required for significant structures, I'm quite happy with the limits my home state of WA place on the practice of structural engineering by engineers who may only hold a Civil license. Any structure for Hazardous, Essential, Emergency, or Critical infrastructure, as well as any structure ...
RE: Structural Insulated Panel Diapgragm
Posted By
Mark Myers
03-21-2021 07:43 PM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Contact Structural Insulated Panel Association for some technical references. https://www.sips.org/about/what-are-sips ------------------------------ Mark Myers, P.E., M.ASCE Gig Harbor, WA ------------------------------
RE: Perforated aluminum panel design
Posted By
Mark Myers
01-29-2021 02:24 PM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
ASCE 7 Figure 29.3-1 Notes 1 & 2 may be a good start. Note 2 includes a force reduction factor based on ratio of solid area to gross area if the openings are more than 30% of gross area. ------------------------------ Mark Myers, P.E., M.ASCE Gig Harbor, WA ------------------------------
RE: Foundation Depth for Egress Stairwell
Posted By
Mark Myers
04-22-2020 02:07 PM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Since this could conceivably lead to damage that could cause a trip & fall injury in the future, I would insist on the deeper excavation. I would also carefully explain the reason why to the owner. ------------------------------ Mark Myers, P.E., M.ASCE Gig Harbor, WA ------------------------- ...
RE: Design for Fire Resistance
Posted By
Mark Myers
12-04-2018 01:42 PM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Older structures will always be more vulnerable, but even newer structures have so far not been required to address the risks seen in these areas. The current building codes are written primarily looking at fires originating within the structure. The building setbacks that address exterior sources are ...
«