Skip main navigation (Press Enter).
Log in
Toggle navigation
Collaborate Home
Communities
My Communities
All Communities
Communities of Practice
Get Started
New User
My Profile
My Privacy Settings
My Email Preferences
FAQs
Browse
Announcements
Blogs
Discussion Posts
Glossary
Library Entries
Connect
Directory
Events
Volunteer
Member Home (Admin)
Log in
New Login Experience Coming!
ASCE will launch a new login experience in early 2026.
List of Contributions
×
Contact Details
Alvi Associates, Inc.
×
Enter Password
Enter Password
Confirm Password
Ribbons
Badges
Mr. Irfan Alvi, P.E., M.ASCE
Alvi Associates, Inc.
Profile
Connections
Contacts
Contributions
Achievements
List of Contributions
Contributions
1 to 5 of 7 total
search criteria =
ALL
RE: FIU Pedestrian Bridge Failure
Posted By
Irfan Alvi
12-06-2019 11:50 PM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
In looking at the NTSB final report, I'm surprised that the report doesn't comment on, or even reference, the submissions made by the other parties to the investigation. Those party submissions can be found in the public docket. I especially recommend reading the party submissions by the designer and ...
RE: FIU Pedestrian Bridge Failure
Posted By
Irfan Alvi
11-04-2019 08:32 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Andres, Thanks for sharing your perspective. From my vantage point in the US, I've never assumed that structural failure rates will be substantially lower in the US than the average for the rest of the world. There may be a degree of 'risk compensation' involved, where greater resources and experience ...
FIU Pedestrian Bridge Failure
Posted By
Irfan Alvi
10-23-2019 11:34 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
The NTSB has completed its investigation of the failure of the FIU pedestrian bridge in Florida. The final report will be released in the next few weeks, and meanwhile an abundance of information can be found at these links: Accident ID HWY18MH009 Mode Highway occurred on March 15, 2018 in Miami, ...
RE: Failure on Paper
Posted By
Irfan Alvi
09-17-2019 11:36 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Chad, Thanks for your response as well. In my office, we generally don't release preliminary or unchecked calculations to clients, we only release final and checked calculations when asked to do so. For concept study and preliminary design submissions, we usually provide reports, drawings, ...
RE: SE/PE exams - should buildings & bridges be separated?
Posted By
Irfan Alvi
09-15-2019 02:45 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
I think that certifications to establish a minimum level of specialized expertise are a necessity for public safety, since they help prevent practitioners from practicing outside their areas of expertise. I was a member of the forensic team which investigated the 2017 Oroville Dam spillway incident in ...
«