Posted By Richard Driscoll 04-22-2020 04:44 PM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Good afternoon Eric, You may wish to consider redesigning the foundation system as a frost-protected system using insulation. I do not know what your frost depth is, but you might be able to get away with placing insulation below the stair and as an apron at the top of the stair. NAHB and HUD have published ...
Posted By Richard Driscoll 04-04-2019 07:44 AM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Hi David, Former NYC foundation engineer here. Usually in New York City, Site Class F is triggered for liquefaction susceptibility. The code has a conservative and overly simplified screening process that is sometimes misapplied leading to false positives. Given what I know about Manhattan subsurface ...
Posted By Richard Driscoll 11-11-2018 10:59 PM
Found In Egroup: Integrated Buildings & Structures
\ view thread
I am a structural engineer, but I started my career as a 'foundation engineer' and had the opportunity to see the exploration, design and construction sides of foundation problems. As such, I have been both a user and generator of geotechnical reports and have seen the collaboration go well or not exist. ...
Posted By Richard Driscoll 11-06-2017 01:59 PM
Found In Egroup: Integrated Buildings & Structures
\ view thread
I assume that you mean the term in some form of the Tergaghi bearing capacity equation that accounts for the overburden or backfill above the footing bearing surface. If you are using some other method, the surcharge term may not apply. As mentioned by others, considering the depth of the foundation ...
Posted By Richard Driscoll 07-28-2017 03:04 PM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Jordan, The allowable lateral bearing capacity and the passive earth pressure are very different things. The passive pressure is the maximum pressure that can be developed on an earth-retaining structure before failing by shearing a displacing a wedge of soil. It can be adapted to a pile but the theories ...