Skip main navigation (Press Enter).
Log in
Toggle navigation
Collaborate Home
Communities
My Communities
All Communities
Communities of Practice
Get Started
New User
My Profile
My Privacy Settings
My Email Preferences
FAQs
Browse
Announcements
Blogs
Discussion Posts
Glossary
Library Entries
Connect
Directory
Events
Volunteer
Member Home (Admin)
Log in
New Login Experience Coming!
ASCE will launch a new login experience in early 2026.
List of Contributions
×
Contact Details
×
Enter Password
Enter Password
Confirm Password
Ribbons
Badges
Mr. Andrew Holmes, P.E., L.S., M.ASCE
Profile
Connections
Contacts
Contributions
Achievements
List of Contributions
Contributions
1 to 5 of 12 total
search criteria =
ALL
RE: Stone Foundation
Posted By
Andrew Holmes
03-10-2019 12:59 PM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
When dealing with old stone foundation, I strongly recommend that your design work avoid modification of the loads on the stone foundation. As long as the foundations are performing acceptably, I generally assume that they can continue to do so, as long as the loaded conditions are not changed. - ...
RE: What is a typical allowance for live loads on residential floors?
Posted By
Andrew Holmes
02-01-2019 07:43 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
The current code in most jurisdictions is 30 PSF for Sleeping Rooms and 40 PSF for other areas. In the 1950's I doubt that much thought went into the floor live loads, and the joists may be undersized. Do you have any additional information about the actual size, span, and spacing of the joists? ...
RE: Single Pole Luminaire Structures
Posted By
Andrew Holmes
02-28-2018 10:07 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
If the pole is damaged, it should be repaired or replaced. If the decision is to repair, the scope of the repair should be determined by either the manufacturer of the pole or a qualified engineer. I disagree that a field inspector should feel pressured to make a decision on the spot, in the field. The ...
RE: Weight of soil acting on a shallow foundation
Posted By
Andrew Holmes
02-24-2018 10:05 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
I typically use (b). Choice (a) would be acceptable if you have a rational basis for your selection. ------------------------------ Andrew Holmes P.E., L.S., M.ASCE Consulting Engineer Melbourne FL ------------------------------
RE: Connection Design Force
Posted By
Andrew Holmes
02-13-2018 09:49 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
In my opinion, you need to design the members and all connection for all of the possible failure modes. If the connection can be subject to both tension and compression loads, then you need to design for both. ------------------------------ Andrew Holmes P.E., L.S., M.ASCE Consulting Engineer Melbourne ...
«
1
2
3
»
Copyright 2025. All rights reserved.
Powered by Higher Logic
×
Community Tags
Add a tag
x
User Tags may not contain the following characters: @ # $ & :