Skip main navigation (Press Enter).
Log in
Toggle navigation
Collaborate Home
Communities
My Communities
All Communities
Communities of Practice
Get Started
New User
My Profile
My Privacy Settings
My Email Preferences
FAQs
Browse
Announcements
Blogs
Discussion Posts
Glossary
Library Entries
Connect
Directory
Events
Volunteer
Member Home (Admin)
Log in
New Login Experience Coming!
ASCE will launch a new login experience in early 2026.
List of Contributions
×
Contact Details
Pendharkar & Associates Ltd
×
Enter Password
Enter Password
Confirm Password
Ribbons
Badges
Mr. Shashank Pendharkar
Pendharkar & Associates Ltd
Profile
Connections
Contacts
Contributions
Achievements
List of Contributions
Contributions
1 to 5 of 12 total
search criteria =
ALL
RE: Loads acting as a Girder
Posted By
Shashank Pendharkar
09-24-2019 07:48 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Ashwin You should clarify whether girder is located e.g. in a Building or Bridge or any other structure e.g. industrial building to support equipment load. If you have a drawing/ skech which shows ocation of girder then that will be help. For a building, assuming concrete floor, you should take dead ...
RE: Working on Existing Foundation for High End Custom Residential Structures
Posted By
Shashank Pendharkar
09-06-2019 07:46 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
In 2017 we strengthened foundation of a 17 story residential building in Dar es Salaam, Tanzania, comprising 800 thk Raft by drilling 10m deep 75mm dia. micro-piles of 300kN capacity each into Sandy Clay soil strata. Micro-piles were chosen because basement with its limited by height could be accessed ...
Jacking up of steel plate girder
Posted By
Shashank Pendharkar
02-10-2019 08:56 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Our bridge comprises of 5 Nos. steel plate girders, each of 61.4m length and 60.8m c/c of bearings + 225mm thk concrete deck slab. Overall Bridge width is 11.15m. Each girder weighs 140 tons including all the steel work. Deck cross section comprises of 5 plate girders at 2125mm c/c with two cantilevered ...
RE: What is a typical allowance for live loads on residential floors?
Posted By
Shashank Pendharkar
02-01-2019 07:43 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
For existing buildings where limited or no information is available we have used 'reverse' engineering approach i.e. to take inventory of existing structure, assess its condition and estimate residual load carrying capacity. Then modify/strengthen the structure as dictated by additional load requirements. ...
RE: Fire requirement for thickness of concrete floor slab
Posted By
Shashank Pendharkar
03-29-2018 10:22 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Thanks for the comments. 1. We followed BS and therefore I mentioned the reference code. Other codes may have different requirements. 2. Slab deflections have been checked in compliance with BS (span/depth ratio) and accordingly reinforcement is increased in midspan. 3. Fire resistance - 2 hour ...
«