Posted By Christopher Hahin 12-14-2020 01:45 PM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Eric, Since you have mentioned that your application is in a coastal city, salt fall will be involved. Also, since I don't know what structure or product you are designing, I don't exactly know what preloads you need for your bolting. In general, I would recommend 2205 stainless steel bolting, which ...
Posted By Christopher Hahin 12-12-2020 05:59 PM
Found In Egroup: Integrated Buildings & Structures
\ view thread
Eric, None of the documents you refer to are applicable to stainless bolts, typically for austenitic stainless steels like 304, 304L and 316 which are commonly available from various sources. For situations involving vibration, the SAE uses a torque value that results in a thread stress that does not ...