Mr. Mandeep Singh Kohli, CP
Profile
Connections
Contacts
Contributions
Achievements
List of Contributions
Contributions
1 to 5 of 12 total
search criteria =
ALL
RE: Continuous Drop Panels
Posted By
Mandeep Singh Kohli
10-30-2020 08:18 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Hi Christian, Flat slab buildings have very low lateral stiffness and hence they are prone to large deflections even for very small levels of shaking. This excessive drift can further amplify the secondary moments on the columns due to P-Delta Effect. This is the reason ACI does not allow the ...
RE: SEI Career Path Series
Posted By
Mandeep Singh Kohli
07-16-2020 09:17 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Hi, These seem like a very good initiative to help engineers manoeuvre these tough times and also help them understand about multiple possible paths they can take in their career. I have registered for all parts. I would love to see the speaker discuss career options for mid level engineers, those ...
RE: Column size reduction and soft story query
Posted By
Mandeep Singh Kohli
07-02-2020 04:23 PM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Hi, You have not mentioned which jurisdiction you fall into, so it may be difficult to suggest. Assuming that you are using ACI code, you may refer clause 10.7.4 of ACI 318 -2019, which gives the required method of how to place the reinforcement when the column faces don't match. For even more detail ...
RE: Anchor Bolt Design with respect to Petrochemical Facilities
Posted By
Mandeep Singh Kohli
06-27-2020 04:07 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Dear Sir, Much thanks and appreciate your response. Your response cleared my doubts. Thanks. ------------------------------ Mandeep Singh Kohli CP, M.ASCE Senior Engineer India ------------------------------
RE: Anchor Bolt Design with respect to Petrochemical Facilities
Posted By
Mandeep Singh Kohli
06-26-2020 06:59 AM
Found In
Egroup:
Integrated Buildings & Structures
\
view thread
Sir, Thank You so much for your response. So that means that the beneficial effects of Tension anchor reinforcement can be used to preclude pry out failure. That clears my doubt. Much thanks to all for chipping in! ------------------------------ Mandeep Singh Kohli CP, M.ASCE Senior Engineer ...
«